Ultra power ZigBee wireless networking technology design;
Real-time monitoring and detection of carbon monoxide gas leakage;
After the alarm, the red LED flashes and sends out the alarm
Working voltage: DC3V (CR123A lithium battery)
Standby current: less than 20uA
Alarm current: less than 60mA
Alarm sound pressure: 85dB/1m
Networking mode: ZigBee ad hoc network
Wireless distance: less than 100 meters (open environment)
Working temperature: -10 C ~+50 C
Ambient humidity: maximum 95%RH
Shape size: 54*54*45mm
Alarm concentration: 30ppm 120 minutes alarm; 50ppm 60-90 minutes alarm; 100ppm 10-40 minutes alarm; 300ppm in 3 minutes.